[email protected]

下列5V0-22.21练习题是VMware 5V0-22.21完整题库的一部分. 5V0-22.21完整练习题库共有149道题. Examook最新5V0-22.21练习题库可以助您顺利通过考试. 如果您使用我们的题库没有效果, 我们将全额退还您的购买费用. 想要测试和学习Eaxmook 5V0-22.21练习题库? 现在开始吧!

 完整 5V0-22.21 练习题库

VMware 5V0-22.21 练习题库

5V0-22.21 w练习题库的更新日期是 2023-05-30 .

正在练习第 1页 ,共 9 页.

正在练习第 1题 ,共 48 道题

题目#1

When attempting to add a directly attached disk device to a host disk group, the intendeddisk does not show among the available devices in disk management.
Which action should be taken?

A. Delete all device partitions
B. Create a 1GB metadata partition
C. Format the existing partition
D. Create a VMFS partition

Explanation:
Reference: https://docs.vmware.com/en/VMware-vSphere/6.7/com.vmware.vsphere.virtualsan.doc/GUID-90CCB01E-DE9C-47DA-9FEF-8B3F107FEA2C.html#GUID-90CCB01E-DE9C-47DA-9FEF-8B3F107FEA2C
https://docs.vmware.com/en/VMware-vSphere/6.7/com.vmware.vsphere.virtualsan.doc/GUID-5D2178B1-FC80-47FE-A0B2-392D5D10BD33.html

题目#2

What is the default health check interval for the vSAN Health services?

A. Every 60 minutes
B. Every 24 hours
C. Every 10 seconds
D. Every 10 minutes

Explanation:
The default health check interval for the vSAN Health services is every 10 minutes. This interval is used by the vSAN Health service to monitor the health of the vSAN cluster and report any anomalies it finds. The vSAN Health service is responsible for running the health checks and if any issues are detected, it will notify the administrator. For more information, see the official VMware guide on vSAN Health Service: https://docs.vmware.com/en/VMware-vSphere/6.7/vsphere-esxi-vcenter-server-67-vsan-health-service-guide.pdf

题目#3

The cluster level backend IOPS performance graph shows a higher-than-average number of IOPS for back-end storage.
What is a possible reason for this situation?

A. Data ^synchronization is in progress.
B. DRS is invoking multiple vMotion migrations.
C. There is VM storage I/O traffic.
D. Not enough capacity for slack space is on vSAN datastore.

Explanation:
Reference: https://core.vmware.com/resource/troubleshooting-vsan-performance

题目#4

A VMware vSAN administrator is configuring advanced monitoring with VMware vRealizeOperations Manager and has the following requirement:
• Ability to receive analytical information from the hard drive to determine a possible future failure of the hard drive.
What should be enabled for data collection when configuring the vSAN Adapter Instance?

A. IOPS (Input/Output Operations Per Second)
B. DST (Disk Self-Test)
C. SMART (Self-Monitoring, Analysis and Reporting Technology)
D. SSP (Storage Service Provider)

Explanation:
Self-Monitoring, Analysis and Reporting Technology (SMART) is an industry-standard technology that allows hard drives to report on their own health, including the ability to predict possible future failures. When configuring the vSAN Adapter Instance in vRealize Operations Manager, the administrator should enable SMART data collection to be able to receive analytical information from the hard drives and monitor their health.
By enabling SMART data collection, the administrator can use the data to identify potential issues with hard drives, monitor their health status, and take appropriate actions to prevent data loss.
This is explained in VMware vSAN documentation in the section "Monitoring vSAN Disk Health with vRealize Operations Manager"
Reference: https://docs.vmware.com/en/VMware-vSphere/7.0/vsphere-vsan-70-admin-guide/GUID-9A9B1E1A-7D56-4C0B-A8C2-2A7E27AED9B9.html

题目#5

A 100GB virtual disk object has this storage policy assigned to it:
✑ Site disaster tolerance: None - standard cluster
✑ Failures to Tolerate: 1 failure - RAID-1 (Mirroring)
✑ Number of disk stripes per object: 3
What is the maximum amount of raw vSAN storage capacity consumed by this virtual disk?

A. 200GB
B. 100GB
C. 300GB
D. 600GB

考题代码: 5V0-22.21考题数: 149 道题更新时间:  2023-05-30